Module 1 - Introduction to Matter, Energy, and Direct Current
Navy Electricity and Electronics Training Series (NEETS)
Chapter 1:  Pages 1-21 through 1-30

[Go to TOC]

 

Module 1 − Introduction to Matter, Energy, and Direct Current

Pages i, 1−1, 1−11, 1−21, 1−31, 1−41, 1−51, 1−61, 2−1, 2−11, 2−21, 3−1, 3−11, 3−21, 3−31, 3−41, 3−51, 3−61, 3−71, 3−81, 3−91, 3−101, 3−111, 3−121, Appendix I, II, III, IV, V, Index

An ammeter with internal shunt resistors - RF Cafe

        Figure 1-22. - An ammeter with internal shunt resistors.

By adding several shunt resistors in the meter case, with a switch to select the desired resistor, the ammeter will be capable of measuring several different maximum current readings or ranges.

Most meter movements in use today have sensitivities of from 5 microamperes to 1 milliampere. Figure 1-22 shows the circuit of meter switched to higher ranges, the shunt an ammeter that uses a meter movement with a sensitivity of 100 microamperes and shunt resistors. This ammeter has five ranges (100 microamperes; 1, 10, and 100 milliamperes; 1 ampere) selected by a switch.

With the switch in the 100 microampere position, all the current being measured will go through the meter movement. None of the current will go through any of the shunt resistors. If the ammeter is switched to the 1 milliampere position, the current being measured will have parallel paths of the meter movement and all the shunt resistors (R1  , R2, R3, and R4). Now, only a portion of the current will go through the meter movement and the rest of the current will go through the shunt resistors. When the meter is switched to the 10-milliampere position (as shown in fig. 1-22), only resistors R1, R2, and R3 shunt the meter. Since the resistance of the shunting resistance is less than with R4  in the circuit (as was the case in the 1-milliampere position), more current will go through the shunt resistors and less current will go through the meter movement. As the resistance decreases and more current goes through the shunt resistors. As long as the current to be measured does not exceed the range selected, the meter movement will never have more than 100 microamperes of current through it.

Shunt resistors are made with close tolerances. That means if a shunt resistor is selected with a resistance of .01 ohms (as R1   in fig. 1-22), the actual resistance of that shunt resistor will not vary from that value by more than 1 percent. Since a shunt resistor is used to protect a meter movement and to allow accurate measurement, it is important that the resistance of the shunt resistor is known very accurately.

Figure 1-22 represents an ammeter with internal shunts. The shunt resistors are inside the meter case and selected by a switch. For limited current ranges (below 50 amperes), internal shunts are most often employed.

 

1-21

For higher current ranges (above 50 amperes) ammeters that use external shunts are used. The external shunt resistor serves the same purpose as the internal shunt resistor. The external shunt is connected in series with the circuit to be measured and in parallel with the ammeter. This shunts (bypasses) the ammeter so only a portion of the current goes through the meter. Each external shunt will be marked with the maximum current value that the ammeter will measure when that shunt is used. Figure 1-23 shows an ammeter that is designed to use external shunts and a d'Arsonval meter movement. Figure 1-23(A) shows the internal construction of the meter and the way in which the external shunt is connected to the meter and to the circuit being measured. Figure 1-23(C) shows some typical external shunts.

An ammeter employing the d'Arsonval principle and external shunts - RF Cafe

Figure 1-23. - An ammeter employing the d'Arsonval principle and external shunts.

A shunt resistor is nothing more than a resistor in parallel with the meter movement. To measure high currents, very small resistance shunts are used so the majority of the current will go through the shunt. Since the total resistance of a parallel circuit (the meter movement and shunt resistor) is always less than the resistance of the smallest resistor, as an ammeter's range is increased, its resistance decreases.

This is important because the load resistance of high-current circuits is smaller than the load resistance of low-current circuits. To obtain accurate measurements, it is necessary that the ammeter resistance be much less than the load resistance, since the ammeter is connected in series with the load.

Q20.    What electrical property does an ammeter measure?

 

1-22

Q21.    How is an ammeter connected to the circuit under test?

 

Q22.    How does an ammeter affect the circuit being measured?

 

Q23.    How is the ammeter's effect on the circuit being measured kept to a minimum?

 

Q24.    What is ammeter sensitivity?

 

Q25.    What is used to allow an ammeter to measure different ranges?

Range Selection

 

Part of the correct use of an ammeter is the proper use of the range selection switch. If the current to be measured is larger than the scale of the meter selected, the meter movement will have excessive current and will be damaged. Therefore, it is important to always start with the highest range when you use an ammeter. If the current can be measured on several ranges, use the range that results in a reading near the middle of the scale. Figure 1-24 illustrates these points.

Reading an ammeter at various ranges - RF Cafe

Figure 1-24. - Reading an ammeter at various ranges.

Figure 1-24(A) shows the initial reading of a circuit. The highest range (250 milliamperes) has been selected and the meter indication is very small. It would be difficult to properly interpret this reading with any degree of accuracy. Figure 1-24(B) shows the second reading, with the next largest range (50 milliamperes). The meter deflection is a little greater. It is possible to interpret this reading as 5 milliamperes. Since this approximation of the current is less than the next range, the meter is switched as

 

1-23

shown in figure 1-24(C). The range of the meter is now 10 milliamperes and it is possible to read the meter indication of 5 milliamperes with the greatest degree of accuracy. Since the current indicated is equal to (or greater than) the next range of the ammeter (5 milliamperes), the meter should NOT be switched to the next range.

AMMETER Safety PRECautionS

When you use an ammeter, certain precautions must be observed to prevent injury to yourself or others and to prevent damage to the ammeter or the equipment on which you are working. The following list contains the MINIMUM precautions to observe when using an ammeter.

·   Ammeters must always be connected in series with the circuit under test.

·   Always start with the highest range of an ammeter.

·   Deenergize and discharge the circuit completely before you connect or disconnect the ammeter.

·   In dc ammeters, observe the proper circuit polarity to prevent the meter from being damaged.

·   Never use a dc ammeter to measure ac.

·   Observe the general safety precautions of electrical and electronic devices.

Q26.    Why should you use the highest range of an ammeter for the initial measurement?

 

Q27.    What range of an ammeter is selected for the final measurement?

 

Q28.    List the six safety precautions for the use of ammeters.

 

Q29.    Why will an ammeter be damaged if connected in parallel with the circuit to be measured?

VOLTMETERS

All the meter movements discussed so far react to current, and you have been shown how ammeters are constructed from those meter movements. It is often necessary to measure circuit properties other than current. Voltage measurement, for example, is accomplished with a VOLTMETER.

VOLTMETERS CONNECTED IN PARALLEL

While ammeters are always connected in series, voltmeters are always connected in parallel. Figure 1-25 (and the following figures) use resistors to represent the voltmeter movement. Since a meter movement can be considered as a resistor, the concepts illustrated are true for voltmeters as well as resistors. For simplicity, dc circuits are shown, but the principles apply to both ac and dc voltmeters.

 

1-24

Current and voltage in series and parallel circuits - RF Cafe

Figure 1-25. - Current and voltage in series and parallel circuits.

Figure 1-25(A) shows two resistors connected in parallel. Notice that the voltage across both resistors is equal. In figure 1-25(B) the same resistors are connected in series. In this case, the voltage across the resistors is not equal. If R1  represents a voltmeter, the only way in which it can be connected to measure the voltage of R2  is in parallel with R2, as in figure 1-25(A).

LoadING EFFECT

A voltmeter has an effect on the circuit being measured. This is called LoadING the circuit. Figure 1-26 illustrates the loading effect and the way in which the loading effect is kept to a minimum.

 

1-25

The loading effect - RF Cafe

Figure 1-26. - The loading effect.

In figure 1-26(A), a series circuit is shown with R1  equaling 15 ohms and R2  equaling 10 ohms. The voltage across R2  (ER2) equals 10 volts. If a meter (represented by R3) with a resistance of 10 ohms is connected in parallel with R2, as in figure 1-26(B), the combined resistance of R2  and R3  (Rn) is equal to 5 ohms. The voltage across R2  and R3  is now 6.25 volts, and that is what the meter will indicate. Notice that the voltage across R1  and the circuit current have both increased. The addition of the meter (R3) has loaded the circuit.

In figure 1-26(C), the low-resistance meter (R3) is replaced by a higher resistance meter (R 4) with a resistance of 10 kilohms. The combined resistance of R2  and R4  (Rn) is equal to 9.99 ohms. The voltage across R2  and R 4  is now 9.99 volts, the value that will be indicated on the meter. This is much closer to the voltage across R2, with no meter (R3  or R4) in the circuit. Notice that the voltage across R, and the circuit current in figure 1-26(C) are much closer to the values in 1-26(A). The current (IR4) through the meter (R4) in figure 1-26(C) is also very small compared to the current (IR2) through R 2. In figure 1-26(C) the meter (R4) has much less effect on the circuit and does not load the circuit as much. Therefore, a voltmeter should have a high resistance compared to the circuit being measured, to minimize the loading effect.

 

1-26

Q30.    What electrical quantity is measured by a voltmeter?

 

Q31.    How is a voltmeter connected to the circuit to be measured?

 

Q32.    What is the loading effect of a voltmeter?

 

Q33.    How is the loading effect of a voltmeter kept to a minimum?

MAKING a VOLTMETER FROM a CURRENT SENSITIVE METER MOVEMENT

The meter movements discussed earlier in this chapter have all reacted to current. Various ways have been shown in which these movements can be used in ammeters. If the current and resistance are known, the voltage can be calculated by the formula E = IR. a meter movement has a known resistance, so as the movement reacts to the current, the voltage can be indicated on the scale of the meter.

In figure 1-27(A), a voltmeter (represented by R2) connected across a 10-ohm resistor with 10 volts applied. The current through the voltmeter (R2) is .1 milliamperes. In figure 1-27(B), the voltage is increased to 100 volts. Now, the current through the voltmeter (R2) is 1 milliampere. The voltage has increased by a factor of 10 and so has the current. This illustrates that the current through the meter is proportional to the voltage being measured.

Current and voltage in parallel circuit - RF Cafe

Figure 1-27. - Current and voltage in parallel circuit.

SENSITIVITY of VOLTMETERS

Voltmeter sensitivity is expressed in ohms per volt (W/V). It is the resistance of the voltmeter at the full-scale reading in volts. Since the voltmeter's resistance does not change with the position of the pointer, the total resistance of the meter is the sensitivity multiplied by the full-scale voltage reading. The higher the sensitivity of a voltmeter, the higher the voltmeter's resistance. Since high resistance voltmeters

 

1-27

have less loading effect on circuits, a high-sensitivity meter will provide a more accurate voltage measurement.

To determine the sensitivity of a meter movement, you need only to divide 1 by the amount of current needed to cause full-scale deflection of the meter movement. The manufacturer usually marks meter movements with the amount of current needed for full-scale deflection and the resistance of the meter. With these figures, you can calculate the sensitivity

equation - RF Cafe

and the full-scale voltage reading full-scale current (full-scale current x resistance).

For example, if a meter has a full-scale current of 50 μA and a resistance of 960Ω, the sensitivity could be calculated as:

equation - RF Cafe

The full-scale voltage reading would be calculated as:

Full-scale voltage reading = full-scale current x resistance

Full-scale voltage reading = 48mV

RANGES

Table 1-1 shows the figures for most meter movements in use today.

Table 1-1. - Meter Movement Characteristics

CURRENT to DEFLECT FULL SCALE

Resistance SENSITIVITY Voltage FULL SCALE

1 mA

   100 Ω

      1 kΩ/VOLT

.1 V

     50 μA

   960 Ω

     20 kΩ/VOLT

.048 V

      5 μA

   5750 Ω

    200 kΩ/VOLT

.029 V

Notice that the meter movements shown in table 1-1 will indicate .029 volts to .I volt at full scale, and the sensitivity ranges from 1000 ohms per volt to 200,000 ohms per volt. The higher sensitivity

 

1-28

meters indicate smaller amounts of voltage. Since most voltage measurements involve voltage larger than .1 volt, a method must be used to extend the voltage reading.

Figure 1-28 illustrates the method of increasing the voltage range of a voltmeter.

A voltmeter and a range resistor - RF Cafe

Figure 1-28. - a voltmeter and a range resistor.

In figure 1-28(A), a voltmeter with a range of 10 volts and a resistance of 1 kilohm (R2) is connected in parallel to resistor R1. The meter has .01 ampere of current (full-scale deflection) and indicates 10 volts. In figure 1-28(B), the voltage has been increased to 100 volts. This is more than the meter can measure. a 9 kilohm resistor (R3) is connected in series with the meter (R2). The meter (R 2) now has .01 ampere of current (full-scale deflection). But since R3  has increased the voltage capability of the meter, the meter indicates 100 volts. R3  has changed the range of the meter.

Voltmeters can be constructed with several ranges by the use of a switch and internal resistors. Figure 1-29 shows a voltmeter with a meter movement of 100 ohms and 1 milliampere full-scale deflection with 5 ranges of voltage through the use of a switch. In this way a voltmeter can be used to measure several different ranges of voltage.

 

1-29

A voltmeter with internal range resistors - RF Cafe

Figure 1-29. - a voltmeter with internal range resistors.

The current through the meter movement is determined by the voltage being measured. If the voltage measured is higher than the range of the voltmeter, excess current will flow through the meter movement and the meter will be damaged. Therefore, you should always start with the highest range of a voltmeter and switch the ranges until a reading is obtained near the center of the scale. Figure 1-30 illustrates these points.

 

1-30

NEETS Modules
- Matter, Energy, and Direct Current
- Alternating Current and Transformers
- Circuit Protection, Control, and Measurement
- Electrical Conductors, Wiring Techniques, and Schematic Reading
- Generators and Motors
- Electronic Emission, Tubes, and Power Supplies
- Solid-State Devices and Power Supplies
- Amplifiers
- Wave-Generation and Wave-Shaping Circuits
- Wave Propagation, Transmission Lines, and Antennas
- Microwave Principles
- Modulation Principles
- Introduction to Number Systems and Logic Circuits
- - Introduction to Microelectronics
- Principles of Synchros, Servos, and Gyros
- Introduction to Test Equipment
- Radio-Frequency Communications Principles
- Radar Principles
- The Technician's Handbook, Master Glossary
- Test Methods and Practices
- Introduction to Digital Computers
- Magnetic Recording
- Introduction to Fiber Optics
Note: Navy Electricity and Electronics Training Series (NEETS) content is U.S. Navy property in the public domain.